| Input |
|
Safe continuos rating ID
at 55 0C with heat sink |
Amp |
55 |
110 |
15 |
30 |
10 |
20 |
08 |
Drain- to-source break
down voltage Vdss(BR) |
VDC |
55 |
55 |
200 |
200 |
500 |
500 |
200 |
Continuos Drain Current
ID@ TC= 25 0C
|
Amp |
98 |
196 |
30 |
60 |
20 |
40 |
18 |
Static drain- to- source
ON resistance rDS (ON) |
Ohm |
0.008 |
0.004 |
0.085 |
0.042 |
0.27 |
0.13 |
0.18 |
Power dissipation pd
@ TC 25oC |
W |
150 |
300 |
190 |
380 |
280 |
560 |
125 |
Repetitive or non repetitive
drain current
|
Amp |
390 |
750 |
180 |
360 |
92 |
180 |
70 |
| Peck diode recovery dv/dt |
V/ns |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
Drain-to-source leakage
current Idss |
MA |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
Maximum junction
temperature Tj (Max) |
0C |
175 |
350 |
150 |
150 |
150 |
150 |
150 |
Thermal resistance
junction to case Rthjc |
0CW |
1.0 |
0.5 |
0.45 |
0.225 |
0.45 |
0.225 |
1 |
ON voltage drop less
than At rated Current |
Vds |
0.45 |
0.45 |
1.3 |
1.3 |
2.7 |
2.7 |
1.7 |
| |
Safe continuos rating ID
at 55 0C with heat sink |
Amp |
04 |
165 |
220 |
45 |
60 |
30 |
40 |
Drain- to-source break
down voltage Vdss(BR) |
VDC |
500 |
55 |
55 |
200 |
200 |
500 |
500 |
Continuos Drain Current
ID@ TC= 25 0C
|
Amp |
8 |
294 |
392 |
90 |
120 |
60 |
80 |
Static drain- to- source
ON resistance rDS (ON) |
Ohm |
0.85 |
0.0026 |
0.002 |
0.028 |
0.021 |
0.09 |
0.0675 |
Power dissipation pd
@ TC 25oC |
w |
125 |
450 |
600 |
540 |
720 |
276 |
368 |
Repetitive or non repetitive
drain current
|
Amp |
30 |
1170 |
1560 |
540 |
720 |
276 |
368 |
| Peck diode recovery dv/dt |
V/ns |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
Drain-to-source leakage
current Idss |
MA |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
Maximum junction
temperature Tj (Max) |
0C |
150 |
175 |
175 |
150 |
150 |
150 |
150 |
Thermal resistance
junction to case Rthjc |
0CW |
1 |
0.33 |
0.25 |
0.15 |
0.11 |
0.15 |
0.11 |
ON voltage drop less
than At rated Current |
Vds |
35 |
0.45 |
0.45 |
1.3 |
1.3 |
2.7 |
2.7 |